A restaurant kitchen is one of the most demanding electrical spaces a small business will ever build. Cooking lines, walk in coolers, dish machines, hood fans and lighting all want power at once. This guide explains how the load is figured, what each major system needs and how to avoid expensive surprises.
Three Davie Electrician team members standing by a rail fence with the company van on a ranch style property

Why the kitchen drives the whole electrical plan

When someone leases a space for a restaurant, the visible parts get most of the attention: the dining room, the signage, the menu, the layout of the tables. The kitchen is behind the scenes, but it is where most of the electricity goes. A busy kitchen is a collection of equipment that each uses a lot of power, and many of them run for hours at a time. The heat they produce adds demand on cooling, and the safety systems they require add more. If the electrical plan is not right from the beginning, the business can face delays, higher costs and operating headaches.

The plan starts with the equipment list. Before an electrician can size anything, they need to know what you will cook and how. A shop that sells sandwiches and coffee has very different needs from one with a full hot line, a pizza oven and a bakery. Gas and electric choices matter too. Some kitchens are all electric, some use gas for the cooking line and electricity for everything else, and some mix by equipment. Every choice has consequences for the electrical load, the gas supply, the ventilation and the building's capacity.

It is common for restaurant owners to choose equipment after signing a lease, and then discover that the building cannot support it without significant upgrades. The space might have a service sized for a small office, or the panel might be full. A lease on a former restaurant is easier, but the previous tenant's equipment may have been different from yours. A wise practice is to talk with an electrician before finalizing the lease and equipment choices. A walk through of the space and a review of the panel can reveal what the building can handle and what will need upgrading.

Another early step is to obtain the specification sheets for each piece of equipment. These documents list voltage, phase, amperage and any special requirements. Voltage and phase are especially important. Commercial kitchen equipment is often made in versions for different electrical services. A fryer, an oven or a dish machine may be built for single phase power or for three phase power, and the building must supply the right type. Choosing the wrong version leads to delay and cost, so check the building's service early.

Remember, too, that the electrical plan interacts with other trades. The mechanical contractor handles the hood and ventilation, the plumber handles water, drains and grease interceptors, the gas fitter handles the fuel. The electrician provides power and controls for many of their devices. Coordination among them, preferably with a shared set of drawings, prevents conflicts. A clear plan also helps the fire marshal and building inspector understand the project.

The remaining sections describe the major systems in the order they are usually planned. They are written in general terms and do not replace the engineered drawings that a restaurant project typically needs. Many jurisdictions require sealed plans for commercial kitchens, and a licensed professional can provide them. Use this guide to prepare for those conversations.

Service size, phases and the main panel

Power reaches a commercial building through a service, a set of conductors from the utility's transformer to a meter and a main disconnect. The service has a voltage and a number of phases. Single phase service is common in homes and small shops. Three phase service has three alternating currents offset in timing, and is used where larger motors and heavy equipment are present. Many commercial kitchens benefit from three phase power, since large equipment such as walk in cooler compressors, dish machines and some ovens run more efficiently on it. Whether a building has three phase available, and what it would cost to bring it in, is a question for the electrician and the utility.

Service size is measured in amps. A small building might have 200 amps, while a full restaurant could need 400, 600 or more depending on the equipment. The electrician determines the needed size by performing a load calculation, which adds the demand of every piece of equipment, applying factors that recognize that not everything runs at full power at once. Commercial kitchen equipment has its own demand factors in the code, reflecting that the more cooking units there are, the less likely they are all running together. The calculation yields a number, and the service must meet or exceed it.

If the existing service is too small, upgrading it can involve a new meter base, new service conductors, a new main panel and coordination with the utility. The utility may need to upgrade the transformer. This process can take weeks or months, depending on the utility and the scale, so it should be started early. Many restaurant openings have been delayed by service upgrades that were not planned in time. Ask your electrician to identify the lead times, and build them into your schedule.

The main panel and the sub panels distribute power to the equipment. A kitchen often has its own panel, located near the cooking line, with breakers for each major piece. This keeps wiring runs short and gives the staff a convenient place to shut off equipment in an emergency. Panels should have spare capacity for future equipment, and every breaker should be clearly labeled. The panel must be in an accessible location with the required working clearances in front of it, and not in a space that gets wet or filled with grease. Tenants often store things in front of panels, which is not allowed, so plan a place for it.

Voltage choices matter. Some kitchen equipment is designed for 208 volt three phase, some for 240 volt single phase and some for 120 volt. The building's service determines which are available. Two common commercial services are 120 over 208 volt three phase and 277 over 480 volt three phase, each with implications. Buying equipment that matches your service avoids needing transformers or costly modifications. The equipment supplier, the electrician and the landlord can confirm this.

Finally, protect the service. Surge protection at the main panel helps defend sensitive equipment such as control boards, point of sale systems and refrigeration controllers. Grounding and bonding must be correct, because a kitchen is full of metal equipment, water and wet floors. Ground fault protection is required for many receptacles in kitchens, and the electrician will include it in the design.

Cooking equipment, hood systems and makeup air

The cooking line is the most obvious electrical load. Electric fryers, griddles, ranges, convection ovens, steamers, salamanders and warmers each draw significant current. Some of the largest units draw tens of amps each. Each unit generally needs a dedicated circuit with a breaker sized for its nameplate. The electrician will connect them with appropriate wire and disconnects, and may use flexible connections where the equipment needs to be moved for cleaning. Locations of disconnects matter, since staff and inspectors need to be able to shut equipment off quickly.

Gas appliances reduce electric load but not entirely. Gas ranges and ovens use electricity for ignition, fans and controls. A gas fryer has electronic ignition and a blower. These small loads still require circuits, and they should be on protected circuits. The gas supply must have an emergency shutoff linked to the fire suppression system in many jurisdictions. That connection is made through the hood system, and the electrician will coordinate with the fire suppression installer.

The hood is a large system. A kitchen exhaust hood removes heat, smoke and grease vapors from over the cooking line. It consists of the hood itself, an exhaust fan on the roof or wall, ducts, and a fire suppression system. The exhaust fan is a large motor, often several horsepower, and it needs its own circuit and starter. The hood lights need power too. In many jurisdictions the exhaust fan must run whenever cooking equipment is on, and interlocks tie the equipment and the fan together, so the cooking equipment cannot run without ventilation.

Makeup air is the counterpart of exhaust. A hood that removes thousands of cubic feet of air each minute needs replacement air to enter the building, or the space will go under negative pressure, making doors hard to open and causing smoke to spill into the dining room. Makeup air units bring in outside air, sometimes heated or cooled, and they are powered by their own motors. The control system coordinates the exhaust and makeup fans. The electrician provides circuits and control wiring, working from the mechanical engineer's drawings.

Fire suppression systems, which discharge extinguishing agents when a fire is detected over the cooking surfaces, are connected to alarms and shutoffs. When the system activates, it can shut down gas and electricity to the cooking equipment, using a shunt trip or a contactor. This requires coordination between the fire system installer and the electrician, and the system must be tested by an authorized technician. The connections are inspected by the fire marshal, so documentation is important.

Special equipment adds more. A pizza oven, a smoker, a rotisserie, a wok station or an induction line each has distinct needs. Induction equipment, in particular, is efficient but draws high power and requires dedicated circuits. If you are considering a new type of equipment, find the specification early, and discuss it with the electrician before your design is final.

Refrigeration, dish machines and hot water

Refrigeration runs around the clock, and its electrical needs are specific. Reach in refrigerators and freezers are usually plug in units on dedicated circuits. Walk in coolers and freezers have remote or attached compressors, evaporator fans, defrost heaters and controls, all of which need power. These are often supplied at higher voltage and may be three phase. The unit's nameplate lists the minimum circuit ampacity and the maximum overcurrent protection. The electrician follows these numbers when selecting wire and breakers.

Because refrigeration protects expensive food, a failure is costly. A tripped breaker at night can spoil an entire inventory. Many operators add temperature monitoring with alarms that notify them if a cooler warms. Ensure the monitoring system has power and, ideally, a battery backup. Place refrigeration on circuits that are not shared with other equipment that may overload them, and on breakers that are labeled and protected from accidental switching.

The dish machine is another substantial load. Commercial dishwashers use electric heating elements to raise water temperature for washing and rinsing. Many include booster heaters to reach sanitizing temperatures. These can draw tens of amps, and they run frequently. The machine has a nameplate with its electrical requirements, and the connections are often hard wired into a disconnect. Water and electricity share the space, so ground fault protection and sealed fittings matter. Also, the exhaust or condensate hood over the machine may need its own power.

Hot water heating can be electric or gas. Electric tankless or storage water heaters draw large loads. A kitchen with sinks, a mop sink, hand sinks and a dish machine may need a robust water heating system. If you choose electric, the load calculation must include it. If gas, the heater may still need electricity for controls and pumps. A recirculation pump keeps hot water available at distant fixtures, and it needs a circuit.

Other equipment includes ice machines, which are high demand and need dedicated circuits, beverage dispensers with chillers, coffee machines, food processors, mixers, slicers and display cases. Each has its own nameplate. Small appliances such as blenders and toasters may be plugged into counter outlets, which must be protected and positioned so cords do not cross wet or hot areas. Receptacles in a commercial kitchen are required to have ground fault protection.

Finally, remember that equipment placement affects wiring. A long run from the panel to a cooler on the far side of the kitchen means larger wire, more conduit and more cost. Locating equipment thoughtfully, and putting the sub panel in a central position, reduces expense. Walls in commercial buildings are often concrete block or metal studs with drywall, and the electrician will choose surface conduit, flexible connections or wall chases accordingly. The method affects cleaning and sanitation too, since smooth sealed surfaces are easier to keep clean.

Lighting, outlets and the safety systems inspectors look for

Lighting in a commercial kitchen serves safety and food handling. Bright, even light lets staff see what they are doing, notice spills and judge the color of food. Fixtures must be sealed against moisture and grease, and many must be shatter resistant so glass does not fall into food. They are often vapor tight, with gaskets and lenses that clean easily. LED fixtures are common because they last long, run cool and use little power. Lighting over cooking areas is installed in the hood or in rated fixtures. Switching should be easy to reach, and some staff prefer lights on a dedicated panel so they cannot be accidentally switched off.

Emergency lighting and exit signs are required in commercial spaces and are a common inspection item. Emergency lights have batteries and turn on when power fails, lighting the path out for a specified period. They must be tested periodically, and the testing must be documented. Exit signs mark the egress paths and must be lit at all times. These devices are on dedicated, unswitched circuits, since they must stay powered.

Outlets should be planned for use. Staff need outlets at prep tables, at the counter, at the pass, in the dining area and at the service area. Outlets in wet or splash areas need ground fault protection and appropriate covers. Floor cleaning in commercial kitchens involves water and hoses, so outlets near floors should be mounted high or protected. Outlets for cleaning machines, phone chargers and the point of sale system must be located so cords do not cross traffic.

Data and communication cabling also needs thought. The point of sale terminals, kitchen display screens, printers and security cameras all require network cable and power. Plan the route for these low voltage cables to keep them away from heat and moisture, and consider a small equipment closet with ventilation and surge protection. A battery backup for the network equipment helps maintain operations through short outages.

The building inspector and the fire marshal look at several safety features. These include fire alarm devices, the suppression system and its connection to the gas and electric shutoffs, clear working space in front of panels, proper labeling, ground fault protection, emergency lighting and exits, and correct installation methods for wiring in cooking areas. Wiring near heat sources must be rated for the temperature. Flexible cords are not a substitute for fixed wiring. Extension cords are not permitted as permanent power. Plan the installation to meet these points from the start.

Accessibility is part of the picture. Controls and switches in public areas may need to be mounted at heights usable by everyone. Restrooms need appropriate lighting, outlets and protective devices. The dining room may have specialty lighting, signage, music systems and displays that demand circuits. A complete plan covers the front of house as well as the kitchen.

Permits, inspections and working with your electrician

A restaurant project involves several permits: building, electrical, mechanical, plumbing, fire, and often health department approval. The electrical permit requires drawings in many cases, showing the load calculation, panel schedules, wiring methods and equipment. A licensed professional prepares and submits them. Inspections occur at stages: rough in, before walls are closed, and final, when equipment is connected and operating. Knowing the sequence helps you schedule the opening.

Start with a phone conversation with an electrician, describing the space, the concept and the equipment you plan to use. They will ask about the size of the kitchen, the seating capacity, the type of cooking and whether the space was a restaurant before. Quotes follow the conversation, but a commercial kitchen always needs an on site visit. Plan to share the lease, floor plan, equipment list and any drawings you have.

At the visit, the electrician will inspect the existing service, meter, panels and wiring. They will check what capacity is available, the type of power, the condition of equipment and the potential routes for new wiring. They may photograph the panel label and the meter. They will ask about the schedule, since restaurant timelines are tight. If you are in a shopping center or building with shared service, they may need to coordinate with the landlord or property manager.

Provide specification sheets as early as possible. The electrician can compile a load schedule and identify problems before purchase. If equipment changes later, tell them promptly, because even a small change, such as swapping a gas fryer for an electric one, can affect the service size. Ask what lead times to expect for materials such as panels, switchgear and transformers, which can be long.

Plan the work sequence with the other trades. Rough in wiring and conduit should be placed before walls and ceilings are closed. Hood installation, plumbing and gas lines should be coordinated with the electrical layout. Equipment delivery should be timed so connections can be made and tested. Allow time for inspections and corrections. Opening day should not be the first time everything is turned on at once.

After completion, request a labeled panel schedule, copies of permits and approvals, and a walkthrough of the shutoffs. Train staff to know where the main disconnect, the kitchen panel and the emergency shutoffs are. Set up a maintenance routine: testing emergency lights, cleaning equipment vents, checking cords and plugs, and inspecting panels for heat or corrosion. A kitchen that is well planned electrically is safer, easier to run and more likely to open on time. If you are starting a restaurant project, a call to an electrician early in the process can save time and money.